CAT: BFP/VCAR
VSR
VSR
VSB
VSR/VSB
IE/VSR-VSB/001/2011 SHEET: 1/1
VS* ** 00
12
VSR
A A1
A A1
A
A1
A1 A
VSB
A
A1
A
A1
Q (l/min)
P(bar)
0
2
3
1
4
6
5
7
0105
35 40 45
20 25 3015
0400
0600
0800
Q (l/min)
P(bar)
0
2
3
1
4
6
5
7
04020
140
80 100 12060
1200
1600
P(bar)
Q (l/min)
0
2
3
1
4
0105
45
20 25
35
30 4015
0400
0600
0800
Q (l/min)
P(bar)
0
2
3
1
4
04020
140
80 100 12060
1200
1600
C
Ch
L
D
C
ØE
A
A1
Regulation stroke
SLEEVE FLOW CONTROL VALVES UNIDIRECTIONAL AND BIDIRECTIONAL - IN-LINE MOUNTING
HYDRAULIC SYMBOLS
HYDRAULIC FEATURES
Hydraulic fluid
DIN 51524 Mineral oils
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
Max. contamin. level class with filter
ISO 4406:1999 - class 19/17/14
Series
Size
ORDERING CODE
FLOW CONTROL VALVES
PRESSURE DROPS
VSR = Unidirectional flow control valve
VSB = Bidirectional flow control valve
00 = Serial N.o.
Completely open valve
Completely closed valve
Service example
Fluid used: mineral based oil with viscosity 15 mm²/s at 40°C.
04 = BSPP 1/4
06 = BSPP 3/8
08 = BSPP 1/2
12 = BSPP 3/4
16 = BSPP 1
Code C
Flow
max
(l/min)
Pressure
max
(bar)
L
(mm)
E
(mm)
D
(mm)
Ch
Weight
(kg)
VSR-VSB 0400
1/4 BSP 15 350 62 31 4.2 19 0.23
VSR-VSB 0600
3/8 BSP 30 350 73 38 4 24 0.42
VSR-VSB 0800
1/2 BSP 45 350 83 45 7.5 30 0.66
VSR-VSB 1200
3/4 BSP 85 300 102 54 10.5 36 1.12
VSR-VSB 1600
1 BSP 130 250 122 65 10 41 1.94
Flow control valve using non compensated throttling.
The flow is reduced in only one direction (A to A1) for VSR valves and in both
directions for VSB valves, by turning the outer casing of the valve right or left.
Slight leakage is tolerated when the control screw or wheel is completely
unscrewed.
It has a galvanised steel body. The check valve ball poppet is in tempered and
ground steel.
Page: 104